作者:
YH Lin,CW Liu,CS Yu
关键词:
EMTP ; electric current measurement ; fault location ; power system measurement ; power transmission faults ; power transmission lines ; synchronisation ; voltage measurement ; EMTP;ATP simulator ; fault locator
摘要:
With the advent of the high synchronization accuracy of modern phasor measurement units (PMUs), a new approach for accurately locating faults on three-terminal lines is proposed. Using the data measured from two terminals of three-terminal lines, the proposed technique can provide an extremely accurate fault location. An EMTP/ATP simulator is used to demonstrate the performance of the proposed fault locator. The simulation results show that the accuracy of fault location is very high under various fault resistance, fault locations, prefault loading conditions, source impedance and fault types
在线下载