空心绝缘管注射后缩短原因分析
The Reason Study of Insulating Hollow Tube Shortening after Injection
DOI: 10.12677/MS.2015.53012, PDF, HTML, XML, 下载: 2,135  浏览: 4,429 
作者: 潘彩红, 丁建兵, 宋 波, 于晓蕾, 陈小娟, 汪 强:江苏神马电力股份有限公司,江苏 南通
关键词: 复合绝缘管缩短固化程度内应力固化剂Composite Insulating Tube Shorten Curing Degree Internal Stresses Curing Agent
摘要: 复合绝缘管在注射后长度出现缩短现象。其主要原因包括以下三个方面:固化程度不完全、绝缘管内应力未完全释放、环境湿度大导致固化剂甲基四氢苯酐水解;且外,本文对绝缘管注射后缩短给出了有效的解决方案。
Abstract: The reasons for the contraction of the tube after injection are as follows: incomplete curing degree, not-fully-released internal stress of the tube, and MTHPA hydrolysis because of the environmental humidity. Furthermore, this paper gives effective solutions for the above problem.
文章引用:潘彩红, 丁建兵, 宋波, 于晓蕾, 陈小娟, 汪强. 空心绝缘管注射后缩短原因分析[J]. 材料科学, 2015, 5(3): 85-87. http://dx.doi.org/10.12677/MS.2015.53012